Home >> Subaru >> 2005 >> Outback R VDC Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (Diagnostic Trouble Code (DTC) Detecting Criteria (H4SO)) >> Diagnostic Trouble Code (DTC) Detecting Criteria >> DTC P0031 H02S HEATER CONTROL CIRCUIT LOW Bank 1 Sensor 1 >> Outline Of Diagnosis

Outline Of Diagnosis

WARNING: This page is about a different variant/trim than selected.

Detect the open or short circuit of heater.

The heater conducts the duty control. The output terminal voltage at ON becomes 0 V, and the output terminal voltage at OFF becomes battery voltage.

Judge NG when the terminal voltage remains Low.