Replace the thermostat if the valve does not close completely at an ambient temperature or if the following test shows unsatisfactory results.

NOTE:
  • Leave the thermostat in the boiling water for more than five minutes before measuring the valve lift.
  • Hold the thermostat with a wire or the like to avoid contacting with container bottom.

Starting temperature to open: 76 - 80 °C (169-176 °F) 

Fully opens: 91°C(196°F) 

Valve lift: 9.0 mm (0.354 in) or more 

Fig 1: Checking Valve Lift Temperature
G03828174Courtesy of SUBARU OF AMERICA, INC.