Abnormality Judgment
WARNING: This page is about a different variant/trim than selected.
- Judge NG when the judgment value is larger than the threshold value after fuel shut-off in deceleration. Response time (Diagnosis value) > Threshold value --> AbnormalNOTE: Variation time of rear oxygen sensor output voltage is short during fuel shut-off in deceleration. Carry out the NG judgment only after the fuel shut-off in deceleration. As for OK judgment, without the condition of fuel shut-off in deceleration, judge OK if the value is below the threshold value.
Judge NG when the malfunction criteria below are completed in 2 seconds after the recovery of fuel shut-off in deceleration which requires 6 seconds or more.
- Judge NG when the O2 sensor voltage after recovery of fuel shut-off in deceleration is large. Judge NG when fuel shut-off in deceleration is also long (6s or more), and although carried out the fuel shut-off in deceleration cut return, when O2 sensor voltage is large (more than 0.55V).
- Judge NG when the judgment value is larger than the threshold value after recovery of fuel shut-off in deceleration.
Response time (Diagnosis value) > Threshold value --> Abnormal
- Judge NG when the O2 sensor voltage after recovery of fuel shut-off in deceleration is small.