Abnormality Judgment
WARNING: This page is about a different variant/trim than selected.
Judge NG when the continuous time until completing the malfunction criteria below becomes more than 15 seconds.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | > 7.98 kPa (59.86 mmHg, 2.36 inHg) |
| Fuel temperature | < 35°C (95°F) |
| Atmospheric pressure | >/= 75.1 kPa (563 mmHg, 22.2 inHg) |
Time Needed for Diagnosis: 15 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as malfunction occurs.