Home >> Subaru >> 2005 >> Outback R VDC Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 13 (Diagnostic Trouble Code (DTC) Detecting Criteria (H4SO U5 (PZEV))) >> Diagnostic Trouble Code (DTC) Detecting Criteria >> DTC P0442 Evaporative Emission Control System Leak Detected (Small Leak) >> Diagnostic Method >> Diagnostic method >> 0.02-inch Diagnosis

0.02-inch Diagnosis

WARNING: This page is about a different variant/trim than selected.

Mode A: (0 point correction) 

Wait until the tank pressure returns to 0 point (0 kPa (0 mmHg, 0 inHg)) when the tank pressure is high. Change to Mode B when the tank pressure becomes 0. Cancel the diagnosis when the tank pressure does not return to 0 point in spite of spending the specified time.

Mode B: (Introduce negative pressure) 

Introduce the intake manifold negative pressure to fuel tank.

About 0 --> -2.0 kPa (0 mmHg --> -15 mmHg, 0 --> -0.59 inHg)

Change to Mode C when the tank pressure becomes the pressure (desired negative pressure) above. Cancel the diagnosis when the tank pressure does not become the value above.

Mode C: (Hold negative pressure) 

Stop introducing the negative pressure and wait the tank pressure returns to the start level of P2 calculation. Change to Mode D when the tank pressure returns to the start level of P2 calculation or when spending the specified time.

Mode D: (Calculation of negative pressure variation) 

Monitor the tank pressure on Mode D, and calculate the tank pressure variation (P2) and time until it returns to the end level of P2 (evpdset). When it returns, change to Mode E. Make advanced OK judgment or cancel depending on the P2 level, when it doesn't return in spite of spending the specified time.

Judge OK when the criteria below are completed.

Judgment Value 

JUDGMENT VALUE

Malfunction Criteria Threshold Value
Advanced OK judgment #1  
Mode D time >/= 30 s
Tank pressure </= -1.8 kPa (-13.4 mmHg, -0.53 inHg)
Advanced OK judgment #2  
Mode D time >/= 200 s
P2 >/= 0.9 - 1.3 kPa (7 - 9.6 mmHg, 0.28 - 0.38 inHg)

Mode E: (Calculation of evaporation gas yield) 

Calculate the tank pressure variation P1 in time evpdset, judge NG/OK from P1 value. (Gray judgment possible)

Abnormal judgment

Judge NG when the criteria below are completed.

Judgment Value 

JUDGMENT VALUE

Malfunction Criteria Threshold Value
P1 < Map 7 value

* Threshold value: map (fuel level vs evpdset)

Map 7 Limit of malfunction criteria for 0.02-inch leak as EVAP. Diagnosis 

MAP 7 LIMIT OF MALFUNCTION CRITERIA

Time evpdset & Fuel level 0 second 30 seconds 50 seconds 100 seconds 160 seconds 200 seconds
10 L (2.6 US gal, 2.2 Imp gal) 0 kPa (0 mmHg, 0 inHg) 0.07 kPa (0.5 mmHg, 0.020 inHg) 0.23 kPa (1.7 mmHg, 0.067 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg)
20 L (5.3 US gal, 4.4 Imp gal) 0 kPa (0 mmHg, 0 inHg) 0.07 kPa (0.5 mmHg, 0.020 inHg) 0.23 kPa (1.7 mmHg, 0.067 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg)
30 L (7.9 US gal, 6.6 Imp gal) 0 kPa (0 mmHg, 0 inHg) 0.07 kPa (0.5 mmHg, 0.020 inHg) 0.23 kPa (1.7 mmHg, 0.067 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg) 0.36 kPa (2.7 mmHg, 0.106 inHg)
40 L (10.6 US gal, 8.8 Imp gal) 0 kPa (0 mmHg, 0 inHg) 0.07 kPa (0.5 mmHg, 0.020 inHg) 0.25 kPa (1.85 mmHg, 0.073 inHg) 0.33 kPa (2.5 mmHg, 0.098 inHg) 0.33 kPa (2.5 mmHg, 0.098 inHg) 0.33 kPa (2.5 mmHg, 0.098 inHg)
50 L (13.2 US gal, 11.0 Imp gal) 0 kPa (0 mmHg, 0 inHg) 0.07 kPa (0.5 mmHg, 0.020 inHg) 0.27 kPa (2.0 mmHg, 0.079 inHg) 0.31 kPa (2.3 mmHg, 0.091 inHg) 0.31 kPa (2.3 mmHg, 0.091 inHg) 0 kPa (0 mmHg, 0 inHg)