Check Power Supply And Ground Circuit
CHECKING POWER SUPPLY AND GROUND CIRCUIT
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK POWER SUPPLY FOR COMBINATION METER.
Connector & terminal (i10) No. 9 (+) - Chassis ground (-) |
Is the voltage more than 10 V? | Go to step 2 . | Check the harness for open or short between ignition switch and combination meter. |
| 2 CHECK POWER SUPPLY FOR COMBINATION METER. Measure the voltage between combination meter connector and chassis ground. Connector & terminal (i10) No. 8 (+) - Chassis ground(-): |
Is the voltage more than 10 V? | Go to step 3 . | Check the harness for open or short between fuse and combination meter. |
3 CHECK GROUND CIRCUIT OF COMBINATION METER.
Connector & terminal (i10) No. 10 - Chassis ground: |
Is the resistance less than 10 ohm? | Replace the combination meter printed circuit. | Repair the wiring harness. |