Check Power Supply And Ground Circuit
POWER SUPPLY AND GROUND CIRCUIT CHART
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK POWER SUPPLY FOR COMBINATION METER.
|
Is the measured value more than 10 V? | Go to step 2. | Check harness for open or short between ignition relay and combination meter. |
| 2 CHECK POWER SUPPLY FOR COMBINATION METER. Measure voltage between combination meter connector and chassis ground. Connector & terminal
|
Is the measured value more than 10 V? | Go to step 3. | Check harness for open or short between fuse and combination meter. |
3 CHECK GROUND CIRCUIT OF COMBINATION METER.
|
Is the measured value less than 10 ohm? | Go to step 4. | Repair wiring harness. |
| 4 CHECK GROUND CIRCUIT OF COMBINATION METER. Measure resistance of harness between combination meter connector and chassis ground. Connector & terminal
|
Is the measured value less than 10 ohm? | Replace combination meter. | Repair wiring harness. |