Grid Filament Test
Start engine. Turn on rear defogger switch. Using a DVOM, measure voltage between ground and center point of each grid line. If DVOM indicates 6 volts, grid line is okay. If DVOM indicates 12 volts or zero volts, grid line is broken. To find broken section, move DVOM positive lead along suspected grid line until sudden change in voltage is indicated.