Operation Check
NOTE:
Perform operation checks before installing new parts.
- Temporarily install ELR assembly under center pillar. Check that lap belt reels in and out properly.
- Gradually tilt ELR assembly. Check that ELR locks so that lap belt cannot be withdrawn when ELR is tilted 45° or more in relation to standard installation angle, and that ELR unlocks when it is tilted within 15°.