Resistance Test (Legacy)
- Remove and unplug fuel tank sending unit. With float at empty position, use an ohmmeter and measure sender resistance. Resistance should be 92 ohms.
- With float at 1/2 full position, sending unit resistance should be 48.5 ohms. With float at full position, sending unit resistance should be 5 ohms. Replace sending unit as necessary.