Valve Lifters
Remove lifters from crankcase. Inspect lifter for wear or clogged oil hole. Replace if lifter-to-crankcase clearance exceeds .004" (.10 mm). Standard clearance is .0012-.0028" (.030-.07 mm).
Remove lifters from crankcase. Inspect lifter for wear or clogged oil hole. Replace if lifter-to-crankcase clearance exceeds .004" (.10 mm). Standard clearance is .0012-.0028" (.030-.07 mm).