Remove/Install Battery Sensor - AR54.10-P-0002SR
MODEL 453
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Remove/install | |||
| 1 | Open maintenance flap | ||
| 2 | Disconnect electrical connector (1) from battery sensor (B95) | ||
| 3 | Unscrew nut (3) from negative terminal on battery and detach ground line (2) | *BA54.10-P-1007-01I | |
| 4 | Remove battery sensor (B95) from negative terminal of on-board electrical system battery (G1) | ||
| 5 | Install in the reverse order |
BATTERY
| Number | Designation | Model 453 | |
|---|---|---|---|
| BA54.10-P-1007-01I | Nut, battery cable to negative terminal/positive terminal of on-board electrical system battery | Nm | 8 |