Remove/install condenser filling valve - AR83.30-P-5536MCC
MODEL 451.3 (except 451.39), 451.4 (except 451.49)
with CODE I01 (Air conditioning Plus)
MODEL 451.39/49
MODIFICATION NOTES
| 8.4.10 | Special tool for removal/installation of diagnostic socket replaced | Operation step 3 |
| Remove/install | |||
| Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Do not perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | AS83.00-Z-0001-01A | |
| Procedure for a damaged or leaky air conditioning system | AH83.30-N-0004-01A | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | AH83.30-N-0005-01A | ||
| Notes on handling refrigerant R134a | AH83.30-N-0003-01A | ||
| 1 | Drain air conditioning system | Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks |
AR83.30-P-1760MCC |
| 2 | Disconnect air conditioning service unit from diagnostic socket of suction line (2) and from diagnostic socket of pressure line (3) | ||
| 000 588 04 82 00 Air conditioning service unit | WS83.00-P-0031B | ||
| 3 | Remove valve insert (1) at diagnostic socket of pressure line (3) | The valve wrench is to be used in model 451 (except 451.391/491). |
|
| Figure | |||
| 4 | Install in the reverse order |