LEMON Manuals: Even more car manuals for everyone
Home >> Smart >> 2015 >> Fortwo Electric Drive, 2D Convertible >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control - 451 Chassis >> Testing & Repair >> Check air conditioning system for leakage >> Check air conditioning system for leakage - AR83.30-P-1761MCE

Check air conditioning system for leakage - AR83.30-P-1761MCE

MODEL 450 

with CODE (I01) Air conditioning Plus 

with CODE (I29) Air conditioning Plus (with combination filter and outside temperature indicator), smart&passion A/C filled 

MODEL 451 with CODE (I01) Air conditioning Plus 

A/C filled 

MODEL 452 with CODE (I01) Air conditioning Plus 

A/C filled 

MODEL 454 

with CODE (I01) Air conditioning Plus 

with CODE (I77) Manual air conditioning 

A/C filled 

  Checking     
DANGER Risk of accident  caused by vehicle starting off by itself when engine is running. Risk of injury  caused by contusions and burns during starting procedure or when working near the engine as it is running Secure vehicle to prevent it from moving by itself.
Wear closed and snug-fitting work clothes.
Do not touch hot or rotating parts.
AS00.00-Z-0005-01A
DANGER Risk of explosion  caused by welding or soldering work on closed air conditioning system. Risk of poisoning  caused by inhaling overheated refrigerant vapors. Risk of injury  to skin and eyes caused by contact with liquid refrigerant. Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. AS83.00-Z-0001-01A
NOTES Procedure for a damaged or leaky air conditioning system   AH83.30-N-0004-01A
IMPORTANT Notes on handling R134a refrigerant Air conditioning with refrigerant R134a AH83.30-N-0003-01A
1 Check complete engine compartment using a UV lamp, remove any contrast agent by washing the engine UV leak detector kit for air conditioning systems  
2 Check refrigerant circuit for leaks using leak-detector additive IMPORTANT Carry out steps as per the operating instructions of the UV leak detection kit.
IMPORTANT Use only the approved MB leak detector additives. If it is proven that a different leak detector additive has been used, we will refuse to reimburse costs inside the warranty and goodwill term. Daimler AG reserves the right to perform reexaminations.
UV leak detector kit for air conditioning systems