Notes on distribution of sealant on crankcase end cover - AH01.40-P-1000-09MNA
ENGINE 177 IN MODEL 205
ENGINE 178 IN MODEL 190
The sealant may only be applied to the specified surfaces in the form of a bead with height and width of 1.0 mm (±0.3 mm).
The sealant must be processed within 10 minutes.
The sealant bead must not be spread.
The sealing surfaces must be cleaned. Use only the sealant indicated in the repair materials.
Mount the end cover within 10 min after application of the sealant.