Check condition of battery - AR54.10-P-1129MCC
MODEL 451.3/4
| Remove | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | Model 451.334/380/480 | AH54.10-P-0002-01MCC | |
| 1 | Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04MCC | |
| 2 | Remove foot support on passenger side | Left-hand drive vehicles | AR68.30-P-1340MCC |
| Right-hand drive vehicles | AR68.30-P-1340MCE | ||
| Check | |||
| 3 | Visual inspection of battery for external leaks | See: ↓ Remove/install battery Left-hand drive vehicles |
AR54.10-P-0005MCC |
| Right-hand drive vehicles | AR54.10-P-0005MCE | ||
| Dispose of battery | OS54.10-P-0001-01Z | ||
| 4 | Check fluid level and correct if necessary | Except model 451.334/380/480, Not when the battery has been replaced. | AP54.10-P-5410MCC |
| 5 | Check battery | AR54.10-P-1129-01A | |
| Cold test current Battery capacity 42 Ah |
*BE54.10-P-1004-01A | ||
| Battery capacity 60 Ah VRLA | *BE54.10-P-1006-01A | ||
| Battery capacity 61 Ah | *BE54.10-P-1008-01A | ||
| Battery capacity 62 Ah Midtronics battery tester |
*BE54.10-P-1009-01A | ||
| Install | |||
| 6 | Install foot support on passenger side | Left-hand drive vehicles | AR68.30-P-1340MCC |
| Right-hand drive vehicles | AR68.30-P-1340MCE |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | All models | |||
|---|---|---|---|---|---|
| BE54.10-P-1004-01A | Battery capacity 42 Ah | Cold test current | as per EN | A | 340 |
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA | Cold test current | as per EN | A | 680 |
| BE54.10-P-1008-01A | Battery capacity 61 Ah | Cold test current | as per EN | A | 540 |
| BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 190 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 480 | ||