Home >> Smart >> 2012 >> Fortwo Pure >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control - General Information >> General Information >> Protect air conditioning circuit and components from moisture when carrying out repair work - AH83.30-N-0005-01A

Protect air conditioning circuit and components from moisture when carrying out repair work - AH83.30-N-0005-01A

MODEL 124, 126, 129, 140, 163, 166, 168, 169, 170, 171, 172, 197, 201, 202, 208, 210, 211, 215, 216, 219, 220, 230, 245, 462 

MODEL 374, 375, 671, 684, 695, 800, 930, 932, 933, 934, 940, 941, 942, 943, 944, 949, 950, 952, 953, 954, 956, 957, 958, 963, 964 

MODEL 375, 673, 674, 675, 676, 958, 967, 970, 972, 974, 975, 976 

MODEL 405, 427, 436, 437 

MODEL 414, 415, 447, 636, 638, 639 

MODEL 450, 451, 452, 453, 454 

MODEL 460 

MODEL 461, 463 up to model year 2013 

MODEL 667, 668, 670 

MODEL 690, 900, 901, 902, 903 (except 903.662), 904, 905, 906 without CODE Z29 (James Cook touring camper, NAFTA) without CODE ZU8 (National version for USA) Except Minibus Sprinter 

MODEL 909 

NOTES

NOTES Do not carry out repair operations on the air conditioning circuit in the open air during damp weather.

Moisture in the refrigerant circuit reduces the system's refrigeration output and leads to damage to the components.

After disconnecting or unscrewing refrigerant lines, immediately seal all connection apertures air tight with suitable stop plugs.

The fluid reservoir or the desiccant cartridge are to be replaced when:

Always store all spare components in a dry, sealed-off area. Do not remove stop plugs in new components until just before they are installed.

Check desiccant cartridge packaging for damage. Dispose of desiccant cartridges with damaged packaging.

Install the desiccant cartridge no later than 20 minutes after opening the packaging.

Further protection against moisture is provided by carefully evacuating the air conditioning system following repair operations. By generating vacuum in the system, the evacuation process removes any moisture that might have penetrated into the system.