Meter Illumination is Always Dark [06/2015 - ]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check if CAN communication DTCs are output.
Refer to DIAGNOSIS SYSTEM [06/2015 - ]
Result
Result Proceed to CAN communication DTCs are not output. A CAN communication DTCs are output. B
Result: 2
B
GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2015 - ]
Result: 1
A
See step 2
- Check if CAN communication DTCs are output.
- READ VALUE USING TECHSTREAM (LIGHT SENSOR ILLUMINANCE)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Illumination Rate Info Illumination rate information 0.00 ms. to 2162.65 ms. Value is output according to ambient light level - Body Electrical > Main Body > Data List
Tester Display Illumination Rate Info Result
Result Proceed to The output value changes according to the ambient light level. A The output value does not change according to the ambient light level. B
Result: 2
B
CHECK CUSTOMIZE PARAMETER SETTING (SENSITIVITY). Refer to CUSTOMIZE PARAMETERS [06/2015 - ]
Result: 1
A
See step 3
- REPLACE MULTIPLEX NETWORK BODY ECU
- Replace the main body ECU (multiplex network body ECU) with a new or known good one.
Refer to REMOVAL [06/2015 - ]
OK
The operation of the combination meter assembly returns to normal.
Result
Proceed to OK NG
Result: 1
OK
END
Result: 2
NG
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2015 - ]
- Replace the main body ECU (multiplex network body ECU) with a new or known good one.