Home >> Scion >> 2016 >> iA Standard Trans >> Repair and Diagnosis >> Accessories & Equipment >> Exterior Lights >> Lighting System (Exterior) - Diagnostic Codes (B131312 - B109911) >> Lighting System >> DTC B1277-11: Reverse Lamp circuit short to ground [07/2015 - ] >> Contents

DTC B1277-11: Reverse Lamp circuit short to ground [07/2015 - ]: Contents

DTC No. Detection Item DTC Detection Condition Warning Indicate Memory Fail-safe Operation Note
B127711 Reverse Lamp circuit short to ground Back-up light circuit malfunction Not applicable DTC Stored Not applicable
  • Drive cycle: Not applicable
  • Self test type: CMDTC self test
DESCRIPTION Back-up light circuit malfunction
DETECTION CONDITION
  • Power source control (power management control ECU) detects a short to ground in the back-up light circuit with the ignition switched ON (engine off or on).
FAIL-SAFE Not applicable
POSSIBLE CAUSE
  • Back-up light bulb (LH) malfunction
  • Back-up light bulb (RH) malfunction
  • Back-up light (LH) connector or terminal malfunction
  • Back-up light (RH) connector or terminal malfunction
  • Power source control (power management control ECU) connector or terminal malfunction
  • Short to ground in wiring harness between the following terminals:
    • Power source control (power management control ECU) terminal E3-12 - Back-up light (LH) terminal E44-1
    • Power source control (power management control ECU) terminal E3-12 - Back-up light (RH) terminal E45-1
  • Power source control (power management control ECU) malfunction