LEMON Manuals: Even more car manuals for everyone
Home >> Scion >> 2016 >> iA Automatic Trans >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge / Display - Diagnostic Codes & Symptom Tests >> Meter / Gauge System >> DTC U2300-56: Central Configuration invalid / incompatible configuration [07/2015 - ] >> Procedure

DTC U2300-56: Central Configuration invalid / incompatible configuration [07/2015 - ]: Procedure

  1. PERFORM COMBINATION METER CONFIGURATION (USING AS-BUILT DATA) 
    1. Using the Techstream, perform the combination meter configuration (using As-Built data).

      Refer to INSPECTION [07/2015 - ]

    2. Clear the DTC for the combination meter using the Techstream.

      Refer to DTC CHECK / CLEAR [07/2015 - ]

      Body Electrical > Instrument Cluster > Clear DTCs 

    3. Retrieve the combination meter DTCs using the Techstream.

      Refer to DTC CHECK / CLEAR [07/2015 - ]

      Body Electrical > Instrument Cluster > Trouble Codes 

    4. Is the same DTC displayed?

      Result

      Proceed to
      Yes
      No

    Result:  2

    Yes 

    See step  5

    Result:  1

    No 

    See step  3

  2. VERIFY THAT REPAIRS HAVE BEEN COMPLETED 
    1. Clear the DTC for the combination meter using the Techstream.

      Refer to DTC CHECK / CLEAR [07/2015 - ]

      Body Electrical > Instrument Cluster > Clear DTCs 

    2. Retrieve the combination meter DTCs using the Techstream.

      Refer to DTC CHECK / CLEAR [07/2015 - ]

      Body Electrical > Instrument Cluster > Trouble Codes 

    3. Is the same DTC displayed?

      Result

      Proceed to
      Yes
      No

    Result:  2

    Yes 

    See step  4

    Result:  1

    No 

    See step  3

  3. VERIFY IF OTHER DTCs DISPLAYED 
    1. Are any other DTCs displayed?

      Result

      Proceed to
      Yes
      No

    Result:  1

    No 

    DTC TROUBLESHOOTING COMPLETED. 

    Result:  2

    Yes 

    REPAIR OR REPLACE THE MALFUNCTIONING PART ACCORDING TO THE APPLICABLE DTC TROUBLESHOOTING. Refer to  DIAGNOSTIC TROUBLE CODE CHART [07/2015 - ] 

  4. REPLACE THE COMBINATION METER. 
    1. Refer to REMOVAL [07/2015 - ]
    2. Then go to the next step.

      Result

      Proceed to
      NEXT

    Result:  1

    NEXT 

    See step  3

  5. USING THE TECHSTREAM, PERFORM THE COMBINATION METER CONFIGURATION (USING AS-BUILT DATA) AGAIN. 
    1. Refer to INSPECTION [07/2015 - ]
    2. Then go to the next step.

      Result

      Proceed to
      NEXT

    Result:  1

    NEXT 

    See step  2