DTC U2300-51: Central Configuration not programmed [07/2015 - ]: Procedure
- PERFORM COMBINATION METER CONFIGURATION (USING AS-BUILT DATA)
- Using the Techstream, perform the combination meter configuration (using As-Built data).
Refer to INSPECTION [07/2015 - ]
- Clear the DTC for the combination meter using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Instrument Cluster > Clear DTCs
- Retrieve the combination meter DTCs using the Techstream. (See 09-02B-7 DTC INSPECTION [combination meter].)
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Instrument Cluster > Trouble Codes
- Is the same DTC displayed?
Result
Proceed to Yes No
Result: 2
Yes
See step 5
Result: 1
No
See step 3
- Using the Techstream, perform the combination meter configuration (using As-Built data).
- VERIFY THAT REPAIRS HAVE BEEN COMPLETED
- Clear the DTC for the combination meter using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Instrument Cluster > Clear DTCs
- Retrieve the combination meter DTCs using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Instrument Cluster > Trouble Codes
- Is the same DTC displayed?
Result
Proceed to Yes No
Result: 2
Yes
See step 4
Result: 1
No
See step 3
- Clear the DTC for the combination meter using the Techstream.
- VERIFY IF OTHER DTCs DISPLAYED
Result: 1
No
DTC TROUBLESHOOTING COMPLETED.
Result: 2
Yes
REPAIR OR REPLACE THE MALFUNCTIONING PART ACCORDING TO THE APPLICABLE DTC TROUBLESHOOTING. Refer to DIAGNOSTIC TROUBLE CODE CHART [07/2015 - ]
- REPLACE THE COMBINATION METER.
- Refer to REMOVAL [07/2015 - ]
- Then go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 3
- USING THE TECHSTREAM, PERFORM THE COMBINATION METER CONFIGURATION (USING AS-BUILT DATA) AGAIN.
- Refer to INSPECTION [07/2015 - ]
- Then go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 2