DTC U2013-13: Switch Pack circuit open [07/2015 - ]: Procedure
- INSPECT CLUSTER SWITCH CONNECTOR CONDITION
- Switch the ignition off.
- Disconnect the negative battery cable.
Refer to REMOVAL [07/2015 - ]
- Disconnect the cluster switch connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
Result
Proceed to Yes No
Result: 1
No
See step 11
Result: 2
Yes
See step 2
- INSPECT COMBINATION METER CONNECTOR CONDITION
- Disconnect the combination meter connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
Result
Proceed to Yes No
Result: 1
No
See step 10
Result: 2
Yes
See step 3
- INSPECT CLUSTER SWITCH CIRCUIT FOR OPEN CIRCUIT
- Verify that the cluster switch and combination meter connectors are disconnected.
- Inspect for continuity between the following terminals (wiring harness-side):
- Combination meter terminal D55-23 - Cluster switch terminal D57-6
- Combination meter terminal D55-1 - Cluster switch terminal D57-2
- Is there continuity?
Result
Proceed to Yes No
Result: 2
No
See step 9
Result: 1
Yes
See step 4
- INSPECT CLUSTER SWITCH
- Inspect the cluster switch.
Refer to INSPECTION [07/2015 - ]
Refer to INSPECTION [07/2015 - ]
Refer to INSPECTION [07/2015 - ]
- Is the cluster switch normal?
Result
Proceed to Yes No
Result: 1
No
See step 8
Result: 2
Yes
See step 5
- Inspect the cluster switch.
- VERIFY THAT REPAIRS HAVE BEEN COMPLETED
- Always reconnect all disconnected connectors.
- Connect the negative battery cable.
Refer to REMOVAL [07/2015 - ]
- Clear the DTC for the combination meter using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Instrument Cluster > Clear DTCs
- Switch the ignition ON (engine off or on) and wait for 5 s or more.
- Retrieve the combination meter DTCs using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Instrument Cluster > Trouble Codes
- Is the same DTC displayed?
Result
Proceed to Yes No
Result: 2
Yes
See step 7
Result: 1
No
See step 6
- VERIFY IF OTHER DTCs DISPLAYED
Result: 1
No
DTC TROUBLESHOOTING COMPLETED.
Result: 2
Yes
REPAIR OR REPLACE THE MALFUNCTIONING PART ACCORDING TO THE APPLICABLE DTC TROUBLESHOOTING. Refer to DIAGNOSTIC TROUBLE CODE CHART [07/2015 - ]
- REPEAT THE INSPECTION FROM STEP 1.
- If the malfunction recurs, replace the combination meter.
Refer to REMOVAL [07/2015 - ]
- Go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 6
- If the malfunction recurs, replace the combination meter.
- REPLACE THE CLUSTER SWITCH.
- Refer to REMOVAL [07/2015 - ]
- Then go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 5
- REFER TO THE WIRING DIAGRAM AND VERIFY WHETHER OR NOT THERE IS A COMMON CONNECTOR BETWEEN THE FOLLOWING TERMINALS:
- Combination meter terminal D55-23 - Cluster switch terminal D57-6
- Combination meter terminal D55-1 - Cluster switch terminal D57-2
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Result: 1
NEXT
See step 5
- REPAIR OR REPLACE THE CONNECTOR.
Result: 1
NEXT
See step 5
- REPAIR OR REPLACE THE CONNECTOR.
Result: 1
NEXT
See step 5