DTC B1C79-13: Front Washer Pump circuit open [07/2015 - ]: Procedure
- INSPECT WASHER MOTOR CONNECTOR CONDITION
- Switch the ignition off.
- Disconnect the negative battery cable.
Refer to REMOVAL [07/2015 - ]
- Disconnect the washer motor connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
Result
Result Yes No
Result: 2
No
See step 11
Result: 1
Yes
See step 2
- INSPECT WASHER MOTOR
- Inspect the washer motor.
Refer to INSPECTION [07/2015 - ]
- Is the washer motor normal?
Result
Result Yes No
Result: 2
No
See step 10
Result: 1
Yes
See step 3
- Inspect the washer motor.
- INSPECT POWER SOURCE CONTROL (POWER MANAGEMENT CONTROL ECU) CONNECTOR CONDITION
- Disconnect the power source control (power management control ECU) connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
Result
Result Yes No
Result: 2
No
See step 9
Result: 1
Yes
See step 4
- INSPECT WASHER MOTOR CIRCUIT FOR OPEN CIRCUIT
- Verify that the washer motor and power source control (power management control ECU) connectors are disconnected.
- Inspect for continuity between the following terminals (wiring harness-side):
- Washer motor terminal A30-2 -power source control (power management control ECU) terminal A27-6
- Washer motor terminal A30-1 - Power source control (power management control ECU) terminal A27-9
- Is there continuity?
Result
Result Yes No
Result: 2
No
See step 8
Result: 1
Yes
See step 5
- VERIFY THAT REPAIRS HAVE BEEN COMPLETED
- Always reconnect all disconnected connectors.
- Connect the negative battery cable.
Refer to REMOVAL [07/2015 - ]
- Clear the DTC for the power source control (power management control ECU) using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Electric Supply Unit > Clear DTCs
- Operate the wiper and washer switch to ON position.
- Retrieve the power source control (power management control ECU) DTCs using the Techstream.
Refer to DTC CHECK / CLEAR [07/2015 - ]
Body Electrical > Electric Supply Unit > Trouble Codes
- Is the same DTC displayed?
Result
Result Yes No
Result: 2
Yes
See step 7
Result: 1
No
See step 6
- VERIFY IF OTHER DTCS DISPLAYED
Result: 1
No
DTC TROUBLESHOOTING COMPLETED.
Result: 2
Yes
REPAIR OR REPLACE THE MALFUNCTIONING PART ACCORDING TO THE APPLICABLE DTC TROUBLESHOOTING.
- REPEAT THE INSPECTION FROM STEP 1.
- If the malfunction recurs, replace the power source control (power management control ECU).
Refer to REMOVAL [07/2015 - ]
- Go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 6
- If the malfunction recurs, replace the power source control (power management control ECU).
- REFER TO THE WIRING DIAGRAM AND VERIFY WHETHER OR NOT THERE IS A COMMON CONNECTOR BETWEEN THE FOLLOWING TERMINALS
- Washer motor terminal A30-2 - Power source control (power management control ECU) terminal A27-6
- Washer motor terminal A30-1 - Power source control (power management control ECU) terminal A27-9
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Result: 1
NEXT
See step 5
- REPAIR OR REPLACE THE CONNECTOR.
Result: 1
NEXT
See step 5
- REPLACE THE WASHER MOTOR.
- Refer to REMOVAL [07/2015 - ]
- Then go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 5
- REPAIR OR REPLACE THE CONNECTOR.
Result: 1
NEXT
See step 5