DTC B1500: Fuel Sender Open Detected [11/2013 - ]: Procedure
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly.
- Check that the float position is between E and F.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition 1 - 2 Float level is F 13.5 to 16.5 Ω 1 - 2 Float level is 1/2 195.3 to 221.3 Ω 1 - 2 Float level is E 405.5 to 414.5 Ω - Reinstall the fuel sender gauge assembly.
NG → See step 3
OK: Go to next step
- Remove the fuel sender gauge assembly.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE)
- Disconnect the C37 combination meter assembly connector.
- Disconnect the H13 fuel sender gauge assembly.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connector Condition Specified Condition C37-17 (L) - H13-2 Always Below 1 Ω C37-22 (E) - H13-3 Always Below 1 Ω C37-24 (ET) - Body ground Always Below 1 Ω C37-17 (L) or H13-2 - Body ground Always 10 kΩ or higher C37-22 (E) or H13-3 - Body ground Always 10 kΩ or higher - Reconnect the fuel sender gauge assembly connector.
- Reconnect the combination meter assembly connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 4
- Disconnect the C37 combination meter assembly connector.
- REPLACE FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL [11/2013 - ]
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2013 - ]