Entire Combination Meter does not Operate: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the D7 combination meter assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition D7-1 (B) - Body ground Always 11 to 14 V D7-2 (IG+) - Body ground Ignition switch ON 11 to 14 V - Measure the resistance according to the value in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D7-20 (ES1) - Body ground Always Below 1 Ω D7-40 (ES2) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly) - Reconnect the D7 combination meter assembly connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- Disconnect the D7 combination meter assembly connector.
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2013 - ]