Entire Combination Meter does not Operate: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND)
- Disconnect the C50 combination meter connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C50-7 (ET) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition C50-6 (IG+) - Body ground Ignition switch ON 11 to 14 V C50-5 (B) - Body ground Always 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL