LEMON Manuals: Even more car manuals for everyone
Home >> Scion >> 2013 >> iQ Base >> Repair and Diagnosis >> Electrical >> Gauges >> Meter / Gauge / Display (Diagnostic Codes & Symptom Tests) (Except Electric) >> Meter / Gauge System >> Symptom Tests >> Operating Light Control Rheostat does not Change Light Brightness >> Procedure

Operating Light Control Rheostat does not Change Light Brightness: Procedure

  1. READ VALUE USING TECHSTREAM (RHEOSTAT SWITCH) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch to ON.
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Combination Meter / Data List.
    5. According to the display on the Techstream, read the Data List.
      COMBINATION METER

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Light Control Switch Display contrast adjust switch
      ON or OFF
      ON: Display contrast adjust switch pressed
      OFF: Display contrast adjust switch not pressed
      -

      OK

      The value displayed on the Techstream changes in according with the actual rheostat switch operation.

    NG → See step   2 

    OK → See step   5 

  2. CHECK HARNESS AND CONNECTOR (JUNCTION BLOCK - LIGHT CONTROL RHEOSTAT) 
    1. Disconnect the D87 light control rheostat connector.
    2. Disconnect the D68 junction block connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Switch Condition Specified Condition
      D68-79 - D87-6 (E) Always Below 1 Ω
      D68-79 or D87-6 (E) - Body ground Always 10 kΩ or higher
    4. Reconnect the light control rheostat connector.
    5. Reconnect the junction block connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT) 
    1. Disconnect the D1 combination meter assembly connector.
    2. Disconnect the D87 light control rheostat connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      D1-11 (SW2) - D87-9 (RV) Always Below 1 Ω
      D1-24 (ET) - Body ground Always Below 1 Ω
      D1-11 (SW2) or D87-9 (RV) - Body ground Always 10 kΩ or higher
    4. Reconnect the combination meter assembly connector.
    5. Reconnect the light control rheostat connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  4. INSPECT LIGHT CONTROL RHEOSTAT 
    1. Inspect light control rheostat. Refer to INSPECTION .
    2. Reinstall the light control rheostat.

    NG → See step   6 

    OK → See step   7 

  5. REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL 
  6. REPLACE LIGHT CONTROL RHEOSTAT. Refer to  REMOVAL 
  7. REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL