Monitor Description
The ECM monitors the output terminal voltage when the vacuum switching valve assembly is actuated. By turning the FET in the ECM on and off, the purge valve assembly is subject to duty control. If the ECM control value (drive signal) and the output terminal voltage duty cycle continue to not match, then the ECM interprets this as a malfunction in the vacuum switching valve circuit, illuminates the MIL, and stores the DTC.