Inspection Procedure
- CHECK COMBINATION METER ASSEMBLY
- Disconnect the F9 gauge connector.
- Check the meter indicator condition.
OK
WIRE CONNECTION AND SPECIFIED CONDITIONWire Connection Condition Specified Condition 2 - 3 Short circuit (Ignition switch ON) Fuel gauge indicator "F" or more (combination meter) - Measure the voltage of the wire harness side connector.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition 2 - Body ground Ignition switch ON 11 to 14 V
NG: Go to step 3
OK: Go to next step
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly.
- Check that the float moves smoothly between F and E.
- Measure the resistance between terminals 2 and 3 of the gauge.
Standard resistance
RESISTANCE SPECIFICATIONFloat Level Specified Condition SF 3.0 to 5.0 Ω Between E and F 3.0 to 111 Ω SE 109 to 111 Ω
NG: REPLACE FUEL SENDER GAUGE ASSEMBLY
OK: REPLACE COMBINATION METER ASSEMBLY
- CHECK WIRE HARNESS (COMBINATION METER - FUEL SENDER GAUGE)
- Disconnect the C6 meter connector.
- Disconnect the F9 gauge connector.
- Measure the resistance of the wire harness side connectors.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Specified Condition C6-23 - F9-2 Below 1 Ω C6-2 - F9-3 Below 1 Ω
NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
OK: REPLACE COMBINATION METER ASSEMBLY