Intermediate Clutch Applies
WARNING: This page is about a different variant/trim than selected.
- 2-3 Shift Solenoid (SS) Valve
-
The 2-3 SS valve is de-energized, blocking feed limit fluid from entering the 2-3 signal fluid circuit. 2-3 signal fluid pressure exhausts through the 2-3 SS valve and 2-3 shift valve spring (372) force moves the 2-3 shift valve (371) to the released position.
- 2-3 Shift Valve
-
2345 fluid is routed through the 2-3 shift valve and enters the intermediate clutch circuit.
- Intermediate Clutch
-
Intermediate clutch fluid is directed to the intermediate clutch piston to apply the intermediate clutch plates and achieve Third gear.