Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Install new O-ring seals (3-4) to the TCC PWM solenoid valve (1), if the O-rings were previously removed.
- Install the TCC PWM solenoid valve (1) into the control valve body.
- Install the TCC PWM solenoid valve retainer into the control valve body.
- Connect the electrical wiring harness connector (1) to the TCC PWM solenoid valve (2).
- Use the proper torque and tightening sequence when installing the valve body.
- Confirm that the manual shift shaft detent lever locating pin is properly engaged with the manual valve link.
- Confirm that the detent spring roller is properly engaged with the manual shift shaft switch.
- Tighten the control valve body bolts. Refer to Control Valve Body Accumulator Assembly Replacement .
- Install the transmission fluid pan and filter. Refer to Automatic Transmission Fluid and Filter Replacement .
- Reset the TAP values. Refer to Transmission Adaptive Functions .
IMPORTANT:
IMPORTANT:
It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, the ECM, PCM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, the ECM, PCM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.