Circuit/System Testing
IMPORTANT:
Do not turn the key to the crank position or engage the starter at any time during diagnosis.
- Ignition OFF, disconnect the engine oil pressure (EOP) switch connector.
- Ignition OFF, test for less than 1 ohm between the ground circuit and ground.
- If greater than 1 ohm, test the ground circuit for an open/high resistance.
- Ignition ON, install a 3-amp fused jumper wire between the signal circuit terminal A and ground. Verify the scan tool Engine Oil Pressure Switch parameter is Low.
- If not Low, test the circuit for a short to voltage or an open/high resistance. If circuit test normal, replace the ECM.
- If all circuits test normal, replace the engine oil pressure switch.