Circuit/System Testing
- Ignition ON, engine ON, verify the scan tool Low Oil Pressure Switch parameter is Closed or the scan tool Low Oil Pressure parameter is Yes.
- If not Closed or Yes, replace the instrument panel cluster (IPC).
- Ignition OFF, disconnect the harness connector at the EOP switch.
- Ignition ON, verify the scan tool Low Oil Pressure Switch parameter is Open or the scan tool Low Oil Pressure parameter is No.
- If not Open or No, test the signal circuit of the EOP switch for a short to ground. If the circuit tests normal, replace the ECM/PCM.
- If all circuits test normal, test or replace the EOP sensor.