LEMON Manuals: Even more car manuals for everyone
Home >> Saturn >> 2006 >> Vue Red Line, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (Automatic Transaxle - 4T45-E - Introduction (2 Of 2)) >> Repair Instructions >> Park/Neutral Position (PNP) Switch Replacement >> Installation Procedure (New Switch)

Installation Procedure (New Switch)

WARNING: This page is about a different variant/trim than selected.
    IMPORTANT: After adjusting the switch, verify the engine only starts in Park or Neutral. If the engine starts in any other position, adjust the switch.
    Fig 1: Removing/Installing PNP Switch At Transaxle
    GM1547448Courtesy of GENERAL MOTORS CORP.
  1. Make sure the transaxle manual shaft is in the Neutral position.
  2. Align the flats on the PNP switch with the transaxle manual shaft and install the PNP switch.
  3. NOTE: Refer to Fastener Notice in Cautions and Notices.
  4. Install the PNP switch bolt (2) and stud (1).

    Tighten:  Tighten the bolt and stud to 20 N.m(15 lb ft).

  5. Connect the PNP switch electrical connector (3).
  6. Fig 2: Removing/Installing Transaxle Range Select Lever At Manual Shaft
    GM1547451Courtesy of GENERAL MOTORS CORP.
  7. Install the transaxle range select lever (3) to the transaxle manual shaft (1).
  8. Install the transaxle range select lever nut (2).

    Tighten:  Tighten the nut to 35 N.m (26 lb ft).

  9. Fig 3: Disconnecting/Connecting Shift Control Cable At Range Select Lever & Bracket
    GM1547449Courtesy of GENERAL MOTORS CORP.
  10. Install the shift control cable and retaining clip (2) to the shift control cable bracket (1).
  11. Install the shift control cable (3) to the range select lever (4).
  12. Verify proper operation of the shift control cable and if necessary adjust the cable.
    1. Place the shift lever in N (Neutral). Rotate the selector shaft clockwise from P (Park) through R (Reverse) into N (Neutral).
    2. With the shift control assembly in N (Neutral) lift the cable connector locking clip up.
    3. Push the clip on the cable connector until fully seated and flush with cable body.