Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Inspect the CKP sensor O-ring and lubricate with a mineral based grease.
- Gently insert the CKP sensor into the block.
- Install the CKP sensor bolt.
Tighten: Tighten the CKP sensor bolt to 8 N.m (71 lb in).
- Reconnect the CKP sensor electrical connector.
- Install the starter. Refer to Starter Motor Replacement (L61) or Starter Motor Replacement (L66) in Engine Electrical.
- Perform the CKP system Variation Learn Procedure. Refer to CKP System Variation Learn Procedure .
NOTE:
Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.