Torque Signal Regulating Valve
WARNING: This page is about a different variant/trim than selected.
IMPORTANT:
Actuator feed fluid continues to feed the 2-3 signal fluid circuit through orifice #6. However, the exhaust port through the 2-3 shift solenoid valve is larger that orifice #6 in order to prevent a pressure increase in the 2-3 signal fluid circuit.
The torque signal regulating valve regulates the line pressure into the torque signal fluid circuit. Filtered actuator feed fluid pressure from the PCS controls this regulation. torque signal fluid pressure is routed to the accumulator valves and to the boost valve in order to control shift feel.