1-2 Shift Valve
WARNING: This page is about a different variant/trim than selected.
The 1-2 shift solenoid valve is Off when the PCM commands the Second gear. A spring force holds the 1-2 shift valve in the upshifted position. Intermediate band feed fluid is routed through the valve and into the intermediate band fluid circuit.