Removal Procedure

WARNING: This page is about a different variant/trim than selected.
CAUTION: Refer to Gasoline/Gasoline Vapors Caution in Cautions and Notices.
    Fig 1: View Of Quick-Connect Fitting Retainer (Metal Collar)
    GM730809Courtesy of GENERAL MOTORS CORP.
  1. Relieve the fuel system pressure before servicing any fuel system connection. Refer to the Fuel Pressure Relief .
  2. Remove the retainer from the quick-connect fitting.
  3. Fig 2: Blowing Dirt Out Of Fitting (Metal Collar)
    GM12776Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Fuel and Evaporative Emission Hose/Pipe Connection Cleaning Notice in Cautions and Notices.
    CAUTION: Refer to Safety Glasses Caution in Cautions and Notices.
  4. Blow dirt out of the fitting using compressed air.
  5. Fig 3: Releasing Quick Connect Locking Tabs (Metal Collar)
    GM12780Courtesy of GENERAL MOTORS CORP.
  6. Choose the correct tool from the J 37088-A  for the size of the fitting. See Special Tools . Insert the tool into the female connector, then push inward in order to release the locking tabs.
  7. Fig 4: Releasing Quick Connect Locking Tabs (Metal Collar)
    GM12782Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Relieving Fuel Pressure Caution in Cautions and Notices.
  8. Pull the connection apart.
  9. Use a clean shop towel in order to wipe off the male pipe end.
  10. Inspect both ends of the fitting for dirt and burrs. Clean or replace the components as required.