LEMON Manuals: Even more car manuals for everyone
Home >> Saturn >> 2006 >> Relay 3.9 1, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Engine Controls - 3.5L - Introduction (2 Of 2)) >> Repair Instructions >> Heated Oxygen Sensor 2 Replacement >> Installation Procedure

Installation Procedure

WARNING: This page is about a different variant/trim than selected.
    Fig 1: View Of HO2S 2
    GM10975Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: A special anti-seize compound is used on the heated oxygen sensor threads. The compound consists of graphite suspended in fluid and glass beads. The graphite will burn away, but the glass beads will remain, making the sensor easier to remove. New or service sensors will already have the compound applied to the threads. If a sensor is removed from an engine and if for any reason is to be reinstalled, the threads must have anti-seize compound applied before reinstallation.
  1. Coat the threads of heated oxygen sensor/catalyst monitor with anti-seize compound GM P/N 5613695, or equivalent if necessary.
  2. NOTE: Refer to Fastener Notice in Cautions and Notices.
  3. Install the HO2S 2.

    Tighten:  Tighten the HO2S 2 (post-catalytic converter) to 41 N.m (30 lb ft).

  4. Connect the sensor electrical connector.
  5. Lower the vehicle. Refer to Lifting and Jacking the Vehicle in General Information.