Conditions for Clearing the DTC
- This DTC requires an ignition cycle in order to change from current to history.
- The BCM no longer detects continuous battery voltage on the RH turn signal monitor circuit for longer than 5 seconds.
- A history DTC will clear after 50 consecutive ignition cycles if the condition for the malfunction is no longer present.