Diagnostic Aids
- If the DTC is a history DTC, the fault maybe intermittent. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
- The following conditions may cause an intermittent malfunction to occur:
- An intermittent short to battery positive voltage in the IP lamps dimming control circuit.
- A poor connection or an intermittent open in the low reference circuit.
- The IP dimmer switch is intermittently shorted to battery positive voltage.
- The BCM is intermittently shorted to battery positive voltage.
DTC B2613
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| Schematic Reference: Interior Lights Dimming Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems. |
||||
| 1 | Did you perform the Lighting System Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems |
| 2 |
|
0.1-13.5 V | Go to Diagnostic Aids | Go to Step 3 |
| 3 |
|
0.1 V | Go to Step 4 | Go to Step 9 |
| 4 |
|
13.5 V | Go to Step 5 | Go to Step 7 |
| 5 |
|
0.1 V | Go to Step 6 | Go to Step 10 |
| 6 | Test the IP lamps low reference circuit for a short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 11 |
| 7 | Test the IP lamp low reference circuit for a short to ground, a high resistance, or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 8 |
| 8 | Test the IP lamps dimming control circuit for a short to ground, a high resistance, or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 11 |
| 9 | Test the IP lamps dimming control circuit for a short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 11 |
| 10 | Inspect for poor connections at the harness connector of the IP dimmer switch. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 12 |
| 11 | Inspect for poor connections at the harness connector of the BCM. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 14 | Go to Step 13 |
| 12 | Replace the I/P dimmer switch. Refer to Instrument Panel (I/P) Dimmer Switch Replacement . Did you complete the replacement? |
- | Go to Step 14 | - |
| 13 |
IMPORTANT:
Perform the setup procedure for the BCM. Refer to Body Control Module (BCM) Programming/RPO Configuration
in Body Control System. Replace the body control module (BCM). Refer to Body Control Module Replacement
in Body Control System.Did you complete the replacement? |
- | Go to Step 14 | - |
| 14 |
|
- | Go to Step 2 | System OK |