Circuit Description
The body control module (BCM) controls the operation of the horns for the security system and remote keyless entry (RKE) functions. Circuit 28 is grounded by the BCM when horn operation is desired. Normal operation of the horn is performed by the horn switch grounding the horn relay and is not controlled by the BCM.