Removal ("G", "L" & "M" Series)
- Discharge A/C system, using approved recovery/recycling equipment. Using a back-up wrench, loosen evaporator inlet (liquid) line fitting at evaporator. Disconnect inlet line. Remove and discard "O" ring(s). Using Orifice Tube Remover/Installer (J-26549-E), remove orifice tube from liquid line.
- If difficulty is encountered during removal of a plugged or restricted orifice tube, remove as much residue as possible. Using a heat gun, carefully apply heat 1/4" from dimples on liquid line. DO NOT overheat line.