Circuit Description
When ignition switch is turned ON, IGNITION 1 voltage is applied to terminal No. 1 of SDM from AIR BAG fuse in instrument panel fuse block, located behind center of dash. SDM performs diagnostics of internal functions while Instrument Panel Cluster (IPC) performs a bulb check by flashing AIR BAG warning light 7 times. If DTC is detected, SDM will command IPC to turn AIR BAG warning light on when bulb check is complete. If no DTC is detected, AIR BAG warning light will go out when bulb check procedure is complete.
NOTE:
For circuit number and wire color identification, See WIRING DIAGRAMS .