Oil Pump Assembly: Inspection
Check bearing on flange for excessive wear or damage. Check machined surfaces for scratches or nicks which may cause fluid leaks. Thoroughly flush oil pump assembly with clean transaxle fluid through pump inlet and outlet passages. While flushing pump, use oil pump drive shaft to rotate oil pump rotor. Allow excess fluid to drain from oil pump assembly.