Diagnostic Procedure
- Determine if DTCs P0740 or P0744 are present. These flags must be eliminated first as a possible cause for DTC P0742.
- Check actuator operation. See ACTUATOR QUICK CHECK under SELF-DIAGNOSTIC SYSTEM. Operation sound of all actuators should be similar.
- Other possibility for DTC P0742 is TCC release circuit leaking at seal ring on input shaft or ball pressed into input shaft is loose.