LEMON Manuals: Even more car manuals for everyone
Home >> Saturn >> 1997 >> SL L4-1.9L SOHC VIN 8 >> Repair and Diagnosis >> Heating and Air Conditioning >> Testing and Inspection >> Component Tests and General Diagnostics >> General, Normal & Specific System Condition Charts >> General System Condition - Refrigerant/Oil Overcharge

General System Condition - Refrigerant/Oil Overcharge







KEY: HIGH PRESSURE SWITCH CYCLES COMPRESSOR ON AND OFF AT HIGH AMBIENT AIR TEMPERATURES.

THEN: System may be operating in an overcharged condition.

^ Confirm by touching the suction and discharge pipes at the compressor. Suction pipe will be cool and discharge pipe will be very hot.
^ An overcharged condition will generate a poor and/or intermittent cooling complaint at higher ambient air temperatures. Intermittent complaints are caused by the pressure switch cycling the compressor On and Off.
^ Reclaim system using an approved recovery system, evacuate and recharge with 0.68 kg (1.50 Lbs.) of R134-a.
^ Run another performance test.