Centre High Mounted Brake Lamp Malfunction
- Ignition OFF, disconnect the harness connector at the E6 Centre High Mounted Stop Lamp.
- Test for less than 5 Ω between the appropriate ground circuit harness connector terminal listed below and ground:
- 4D -E6 High-Level Centre Brake Light connection 2
- 5D -E6 High-Level Centre Brake Light connection 1
- If greater than the specified range, test the ground circuit for an open circuit/high resistance.
- Connect a test lamp between the appropriate control circuit harness connector terminal listed below and ground:
- Run the test of the center brake light command using a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- 4D -E6 High-Level Centre Brake Light connection 3
- 5D -E6 High-Level Centre Brake Light connection 2
- Run the test of the center brake light command using a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the test shows that the circuit is normal, replace the body electronic module K9.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the test shows that the circuit is normal, replace the body electronic module K9.
- If all circuits test normal, replace the E6 Centre High Mounted Stop Lamp.