Reading Lamps Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate reading lamp.
- E37A Dome/Reading Lamps harness connector X8
- E37B Dome/Reading Lamps - 2nd Row harness connector X1
- Verify the following components are switched OFF:
- A3L Sunshade - Left
- A3R Sunshade - Right
- E27 Instrument Panel Compartment Lamp
- Test for less than 5 Ω between the ground circuit terminal 6 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, test for greater than 11 V between the 12 V circuit terminal 1 and the ground circuit terminal 6.
- If less than the specified value, test the circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.
- If all circuits test normal, test or replace the inoperative reading lamp bulb or reading lamp.
- E37A Dome/Reading Lamps
- E37B Dome/Reading Lamps - 2nd Row