Hazard Switch Indicator Malfunction

  1. Ignition OFF, disconnect the harness connector at the S26 Hazard Lamps Switch.
  2. Ignition OFF, verify a test lamp illuminates between B+ and the ground circuit terminal 1.
  3. If the test lamp does not illuminate, test the ground circuit for an open circuit/high resistance.
  4. Ignition ON, test for greater than 11 V between the circuit terminal 5 and the ground.
  5. If less than the specified value, test the circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.
  6. Ignition OFF, install a 3 A fused jumper wire between the signal circuit terminal 4 and ground.
  7. If all circuits test normal, replace the S26 Hazard Lamps Switch.